BJ-1 Disintegration Tester
Descriptions
BJ series of instruments are used for detecting disintegration of solid in prescriptive conditions.
Applicable standards:
National standard (Chinese codex)/2005/
Corporate standard (Disintegration tester) Q/12XQ0188-2004
Features
- There are six tubes in one basket assembly.
- Auto stop at timing point.
- The bath liquid can achieve an even temperature.
- AMPU is used to automatically control the temperature, time and frequency of nacelle up and down.
- Parameters can be preset at anytime. The preset and real data can be displayed alternately in time.
- Automation: auto-test, auto-diagnose, auto-alarm.
Technical Parameters
Basket assembly | 1 |
Nacelle up and down frequency | 30 - 32 time/min |
Nacelle up and down range | 54-56 mm |
Automatic time range | 1-900 minutes |
Time accuracy | +/- 0.5 minute |
The cubage of beaker | 1000 ml |
The quantity of glass tube | 6 pcs |
Controlling temperature range | Room temperature to 45º Celsius |
Accuracy of controlling temperature | +/- 0.5º Celsius |
Power | 600 W |
Power supply | AC, 220V/50HZ or 110V/60HZ 1 phase |
Net weight | 11 kg |
Overall size | 260 x 300 x 420 mm |
BJ-2 Disintegration Tester
Descriptions
BJ series of instruments are used for detecting disintegration of solid in prescriptive conditions.
Applicable standards:
National standard (Chinese codex)/2005/
Corporate standard (Disintegration tester) Q/12XQ0188-2004
Features
- There are twelve tubes in two basket assemblies.
- Each test station is driven independently. Auto stop at timing point.
- The bath liquid can achieve an even temperature.
- AMPU is used to automatically control the temperature, time and frequency of nacelle up and down.
- Parameters can be preset at anytime. The preset and real data can be displayed alternately in time.
- Automation: auto-test, auto-diagnose, auto-alarm.
Technical Parameters
Basket assembly | 2 |
Nacelle up and down frequency | 30 - 32 time/min |
Nacelle up and down range | 54-56 mm |
Automatic time range | 1-900 minutes |
Time accuracy | +/- 0.5 minute |
The cubage of beaker | 1000 ml |
The quantity of glass tube | 12 pcs |
Controlling temperature range | Room temperature to 45º Celsius |
Accuracy of controlling temperature | +/- 0.5º Celsius |
Power | 600 W |
Power supply | AC, 220V/50HZ or 110V/60HZ 1 phase |
Net weight | 16 kg |
Overall size | 400 x 300 x 420 mm |
BJ-3 Disintegration Tester
Descriptions
BJ series of instruments are used for detecting disintegration of solid in prescriptive conditions.
Applicable standards:
National standard (Chinese codex)/2005/
Corporate standard (Disintegration tester) Q/12XQ0188-2004
Features
- There are eighteen tubes in three basket assemblies.
- Each test station is driven independently. Auto stop at timing point.
- The bath liquid can achieve an even temperature.
- AMPU is used to automatically control the temperature, time and frequency of nacelle up and down.
- Parameters can be preset at anytime. The preset and real data can be displayed alternately in time.
- Automation: auto-test, auto-diagnose, auto-alarm.
Technical Parameters
Basket assembly | 3 |
Nacelle up and down frequency | 30 - 32 time/min |
Nacelle up and down range | 54-56 mm |
Automatic time range | 1-900 minutes |
Time accuracy | +/- 0.5 minute |
The cubage of beaker | 1000 ml |
The quantity of glass tube | 18 pcs |
Controlling temperature range | Room temperature to 45º Celsius |
Accuracy of controlling temperature | +/- 0.5º Celsius |
Power | 600 W |
Power supply | AC, 220V/50HZ or 110V/60HZ 1 phase |
Net weight | 22 kg |
Overall size | 540 x 300 x 420 mm |